Lutron WAC-2019SD pH/ORP, DO, CD/TDS, SALT / Hardness / Resistance Meter
Harga
Rp100,-
Tersedia
Lutron WAC-2019SD pH/ORP, DO, CD/TDS, SALT/ Hardness/ Resistance Meter
LUTRON WAC-2019 is a Water Quality meter and SD Card real time data recorder. Real time recorder, save the data into the SD memory card (1GB to 16 GB) and can be downloaded to the Excel, extra softwereis no need.pH/ORP, DO, CD/TDS, SALT / Hardness/ Resistance Meter
"Produk WAC-2019SD termasuk 1 sensor CDPB-04/ Conductivity/TDS/Salinity/ Hardness"
Fitur Lutron WAC-2019SD pH/ORP, DO, CD/TDS, SALT / Hardness/ Resitance Meter :
Satu meter untuk operasi serbaguna: pengukuran PH/ORP, CD/TDS, Oksigen Terlarut, GaramTampilkan 4 parameter secara bersamaan
Pengukur oksigen terlarut menggunakan probe oksigen tipe grafis kutub dengan sensor suhu, pengukuran presisi tinggi untuk Dissolved Oxygen (DO) dan pengukuran suhu
Probe oksigen terlarut tugas berat, kepala probe dapat terhubung dengan botol BOD
LCD TFT 2,4″ dengan lampu latar lampu hijau, agar mudah dibaca
Spesifikasi Lutron WAC-2019SD Water Quality Recorder :
Real time SD memory card Datalogger, sampling time set
from 1,2,5,10,30,60,120,300,600,1800,3600second
PH
PH Optional,
Measurement PH 0 to 14 PH resolution 0.01 PH, accuracy ±(0.02 PH + 2 d)
ORP
mV -1999 mV to 1999 mV
Res: 1 mV , Accuracy ±(0.5% + 2 d)
Temperature
Manual: 0 to 100 ℃, be adjusted by Compensation push button on front panel.
Automatic With the optional temperature probe ( TP-07 ) 0 to 65 ℃.
2a. Conductivity ( Accuracy ± 2% F.S.+1d )
200 uS 0 to 200.0 uS 0.1 uS
2 mS 0.2 to 2.000 mS 0.001 mS
20 mS 2 to 20.00 mS 0.01 mS
200 mS 20 to 200.0 mS 0.1 mS
2b. TDS ( Total Dissolved Solids / Accuracy± 2% )
Range 1: PPM 0 to 132 PPM / 0.1 PPM
Range 2 : 132 to 1,320 PPM / 1 PPM
Range 3 : 1,320 to 13,200 PPM / 10 PPM
2Range 4: 13,200 to 132,000 PPM / 100 PPM
Salt
Measurement 0 to 12 % salt ( % weight ).
Res: 0.01 % salt.
Accuracy 0.5 % salt value
Temperature Compensation Automatic 0 to 60 ℃
Hardness
Range Measurement Resolution ( Accuracy ±2%F.S.+1d)
10 PPM 0 to 10.00 PPM 0.01 PPM
100 PPM 0 to 100 PPM 0.1 PPM
1,000 PPM 100 to 1,000 PPM 1 PPM
10,000 PPM 1,000 to 10,000 PPM 10 PPM
100,000 PPM 10,000 to 100,000 PPM 100 PPM
3c. Resistivity Accuracy ±(2% F.S.+1d)
automatic 5 ohm to 1 ohm
Range 99.99 M ohm 0.01 M ohm
Dissolved oxygen
Measurement DO: 0 to 20.0 mg/L Resolution: 0.1 mg/L.
Accuracy : ±0.4 mg/L.
Oxygen in Air 0 to 100.0 %, Resolution: 0.1 %
Accuracy : ±0.7% O2.
Temperature 0 to 50 ℃. Res: 0.1 ℃.
Accuracy: ±0.8 ℃
Accessories included :
- Instruction Manual
- Probe CDPB-04 Conductivity/TDS/Salt/ Hardness probe